The vacuum pump of a VSA or VPSA nitrogen generator is a potentially fire hazard because the oil in it can get too hot. This has manifested itself numerous times over the years in engine room fires, or worse. Blue Atmosphere has a unique, standard protection that switches off the generator at temperatures higher than 115 °C. The controller in the machine gives an alarm, and you can see what is going on, because the machine controller is remotely accessible.

As far as we know, competing systems do not have this protection. We now offer you a simple and inexpensive solution to convert your system. If you are interested in this, please contact our service department. www.blueatmosphere.nl/contact.